DesignerWall® Fencing
View DetailModule Column Centre Spacing (mm) 2400, 3000 Module Panel Width (mm) 2300, 2900 Module Height (mm) 900, 1200, 1800, 2100, 2400 and 3000* (*depends on panel height & post engineering) Module Panel thickness (mm) 50, 75 COLORBOND® Yes Column Material Aluminium Column Size (mm) Width: 140 Depth: 105 Availability Nationally Thickness/R-Values Thickness 50 75 Typical Mass (kg/m2) 11.3 11.6 SL Grade Declared λ (W/m.K) at 23℃ 0.042 0.042 SL Grade Declared R-value (m2K/W) at 15℃ (NZ) 1.25 1.85 SL Grade Declared R-value (m2K/W) at 23℃ (AUS) 1.20 1.80 Note: The Declared R-value is at 23℃ in accordance with AS/NZS 4859.1:2018 & AS/NZS 4859.2:2018. Information Guide Product Specification -
Equitilt® Architectural Walling
View DetailModule Width 1200 COLORBOND® Yes BCA Compliant Yes Availability Nationally CodeMark™ Accredited Yes Thickness/R-Values Thickness 50 75 100 125 150 200 250 Declared R-value (m2K/W) at 23℃ 1.20 1.80 2.40 3.00 3.60 4.85 6.05 Total R-value (m2K/W) at 15℃ (Winter) 1.41 2.04 2.66 3.28 3.91 5.16 6.41 Total R-value (m2K/W) at 30℃ (Summer) 1.36 1.94 2.53 3.13 3.72 4.91 6.09 CodeMark Certificate of Conformity - Equitilt® CodeMark Certificate of Conformity - Equitilt® FlameGuard® BAL/Bushfire Compliance Technical Data Sheets - Equitilt® Technical Data Sheet - Equitilt® FlameGuard® Product Specification - Equitilt® Product Specification - Equitilt® FlameGuard® Bondor MSDS -
Equitilt FlameGuard® Non-Combustible Cladding & Fire Rated Walls
View DetailModule Width 1200 FM Approved Yes COLORBOND® Yes BCA Compliant Yes Availability Nationally CodeMark™ Accredited Yes Thickness/R-Values Thickness 50 75 100 150 Declared R-value (m2K/W) at 23℃ 1.36 2.04 2.72 4.09 Total R-value (m2K/W) at 15℃ (Winter 1.58 2.29 3.00 4.41 Total R-value (m2K/W) at 30℃ (Summer) 1.48 2.13 2.79 4.11 CodeMark Certificate of Conformity - Equitilt FlameGuard® CodeMark Certificate of Conformity - LuxeWall® FlameGuard® BAL/Bushfire Compliance Technical Data Sheet - Equitilt FlameGuard® Technical Data Sheet - LuxeWall® FlameGuard® Product Specification - Equitilt FlameGuard® Product Specification - LuxeWall® FlameGuard® Bondor MSDS - Equitilt FlameGuard® -
MetecnoSpan®PIR Roofing
View DetailModule Width 1000 FM Approved Yes COLORBOND® Yes BCA Compliant Yes CodeMark™ Accredited Yes GreenRate Certified Yes Availability National Thickness/R-Values Thickness 40 60 80 100 Declared R-value (m2K/W) at 23℃ 1.85 2.75 3.65 4.55 Total R-value (m2K/W) at 15℃ (Winter) 2.10 3.05 4.00 4.94 Total R-value (m2K/W) at 30℃ (Summer) 2.00 2.87 3.74 4.61 CodeMark Certificate of Conformity BAL/Bushfire Compliance Technical Data Sheet Product Specification Bondor MSDS -
SolarSpan® Insulated Roof Panel
View DetailModule Width 1000 COLORBOND® Yes BCA Compliant Yes Availability Nationally, Manufactured Locally CodeMark™ Accredited Yes Thickness/R-Values Thickness 50 75 100 125 150 175 200 Declared R-value (m2K/W) at 23℃ 1.20 1.80 2.40 3.00 3.60 4.25 4.85 Total R-value (m2K/W) at 15℃ (Winter) 1.40 2.03 2.65 3.27 3.90 4.52 5.15 Total R-value (m2K/W) at 30℃ (Summer) 1.38 1.98 2.57 3.13 3.76 4.35 4.95 CodeMark Certificate of Conformity BAL/Bushfire Compliance Technical Data Sheet Product Specification Information Guide Residential Roofing Span Table Bondor MSDS -
Equideck® Flat Roofing
View DetailModule Width 1200 COLORBOND® Yes BCA Compliant Yes Availability Nationally, Manufactured Locally CodeMark™ Accredited Yes Thickness/R-Values Thickness 50 75 100 125 150 200 250 Declared R-value (m2K/W) at 23℃ 1.20 1.80 2.40 3.00 3.60 4.85 6.05 Total R-value (m2K/W) at 15℃ (Winter) 1.40 2.06 2.65 3.27 3.90 5.15 6.40 Total R-value (m2K/W) at 30℃ (Summer) 1.38 1.98 2.57 3.17 3.76 4.95 6.13 CodeMark Certificate of Conformity BAL/Bushfire Compliance Technical Data Sheets Product Specification Bondor MSDS -
SecureLap®Patented End Lap System
View DetailAvailability National CodeMark™ Accredited Yes SecureLap Information Guide -
MetecnoInspire®PIR Secret-Fix Wall Panel
View DetailModule Width 1100 FM Approved Yes COLORBOND® Yes BCA Compliant Yes Availability Nationally CodeMark™ Accredited Yes Thickness/R-Values Thickness 50 60 80 100 Declared R-value (m2K/W) at 23℃ 2.20 2.65 3.55 4.45 Total R-value (m2K/W) at 15℃ (Winter) 2.49 2.96 3.89 4.83 Total R-value (m2K/W) at 30℃ (Summer) 2.31 2.74 3.60 4.46 CodeMark Certificate of Conformity BAL/Bushfire Compliance Technical Data Sheet Product Specification Information Guide